Medium Static Pressure Duct ARYA45LCTU

Hydraulic unit and Outdoor unit

All DC models R410A 10 Years Warranty
Indoor Unit :
ARYA45LCTU
Outdoor Unit :
AOYA45LCTL
Download :
Catalogue

Features

  • Slim & Compact design
  • Easy maintenance
  • Easy installation
  • Two-direction drain piping
  • Low ambient operation

Feature Explanation Icons

Automatic fan speed : The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature. Auto restart : In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored. Auto-changeover : The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature. Connectable distributing duct : Systems are capable of attaching field-supplied branch ducts distributing the airflow. Connectable fresh air duct : Outside air can be introduced by attaching field supplied duct to fresh air knockout and optional part. Economy mode : Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating. Weekly + setback timer : Weekly + Setback timer can set temperature for two times spans and for each day of the week. Filter sign : Indicates the filter cleaning period by lamp.

Capacity

Cooling  12.0 kW
Heating  13.3 kW

Recommended static pressure : 30 - 150


Specification

Power source Phase Single-phase
Voltage 220 V
Frequency 50 Hz
Capacity Cooling 41,000 BTU/h (13,700 - 45,400) BTU/h
Heating 45,400 BTU/h (14,300 - 52,900) BTU/h
Cooling 12.0 kW(4.0 - 13.3) kW
Heating 13.3 kW (4.2 - 15.5) kW
Input Power Cooling 3.74 kW
Heating 3.68 kW
EER Cooling 3.21 W/W
COP Heating 3.61 W/W
Running Current Cooling 16.4 A
Heating 16.1 A
Moisture Removal 4.0 I/h
Sound Pressure Level Indoor (Cooling) High 42 dB(A)
Middle 38 dB(A)
Low 32 dB(A)
Quiet 28 dB(A)
Outdoor 55 dB(A)
Air Flow Rate Indoor High 2100 m3/h
Outdoor High 6750 m3/h
Net Dimensions
Indoor
Height 270 mm
Width 1135 mm
Depth 700 mm
Net Dimensions
Outdoor
Height 1290 mm
Width 900 mm
Depth 330 mm
Net Weight Indoor 40 kg
Outdoor 86 kg
Connection Pipe Diameter Liquid 9.52 mm
Gas 15.88 mm
Drain Hose Diameter Indoor 36.0 mm
Outdoor 38.0 mm
Max Pipe Length (Pre Charge) 50 (20) m
Max Height Difference 30 m
Operation Range Cooling -15 to 46 °CDB
Heating -15 to 24 °CDB
Refrigerant Type R410A
Scroll

Dimensions

Indoor Unit : ARYA45LCTU

Indoor unit

Optional Parts

Wired Remote Controller
UTY-RNNYM
Simple Remote Controller
UTY-RSNYM
Flange
UTD-RF204 (Round)
Flange
UTD-SF045T (Square)
Long-Life Filter
UTD-LF25NA
Remote Sensor Unit
UTY-XSZX
External Connect Kit
UTY-XWZXZ2
External Connect Kit
UTY-XWZXZ3
External Control Set
UTD-ECS5A
Drain Pump Unit
UTZ-PX1NBA
IR Receiver Kit
UTY-LRHY1
IR Receiver Kit
UTY-LRHYM