變頻一對多空調系統 室內機搭配組合
連接室內機的型式
| 室外機 | 型式 | 2室 | 3室 | 4室 | 4室 | |
|---|---|---|---|---|---|---|
| 機型 | AOCG050LBTA2![]() |
AOCG072LBTA3![]() |
AOCG084LBTA4![]() |
AOCG100LBTA4![]() |
||
| 冷房(kW) | 5.0 | 7.2 | 8.0 | 10.0 | ||
| 暖房(kW) | 6.0 | 8.4 | 9.4 | 10.5 | ||
| 室内機 | CSPF | 5.51 | 5.12 | 5.24 | 5.31 | |
| 壁掛式 | ASCG022LMTC | 2.2 | ||||
| ASCG028LMTC | 2.8 | |||||
| ASCG036LMTC | 3.6 | |||||
| ASCG040LMTC | 4.0 | - | ||||
| ASCG050LFTC | 5.0 | - | ||||
| ASCG063LFTC | 6.3 | - | - | |||
| ASCG071LFTC | 7.1 | - | - | |||
| 埋入式 | ARCG022LSTA | 2.2 | ||||
| ARCG028LSTA | 2.8 | |||||
| ARCG036LSTA | 3.6 | |||||
| ARCG036LSTB | 3.7 | - | ||||
| ARCG040LSTA | 4.0 | - | ||||
| ARCG050LSTA | 5.0 | - | ||||
| ARCG050LSTB | 5.2 | - | ||||
| ARCG063LSTA | 6.3 | - | - | |||
| ARCG071LSTA | 7.1 | - | - | |||
滾動
室內機組合參考
配合房間的用途可以有多種組合方式。
AOCG050LBTA2 (2室)
4.4kW ̶ 6.4kW 最高連結率128%
| 組合方式 | 空間1 | 空間2 |
|---|---|---|
| 1 | 2.2 | 2.2 |
| 2 | 2.2 | 2.8 |
| 3 | 2.2 | 3.6 |
| 4 | 2.8 | 2.8 |
| 5 | 2.8 | 3.6 |
| 配管限制 | ||
|---|---|---|
| 最大配管長(全長) | 50m | |
| 最大配管長(各室內-室外) | 25m | |
| 最大高低差(室內-室外) | 15m | |
| 最大高低差(室內-室內) | 10m | |
| 最小配管長(各室內-室外) | 5m | |
| 最小配管長(全長) | 15m | |
| 內含冷媒量長度 | 30m | |
| 冷媒追加填充量 | 20g/m | |
| 接續配管 | 液管徑 | ø6.35mm(2分) |
| 氣管徑 | ø9.52mm(3分) | |
AOCG072LBTA3 (3室)
5.6kW ̶ 10.0kW 最高連結率139%
| 組合方式 | 空間1 | 空間2 | 空間3 |
|---|---|---|---|
| 1 | 2.2 | 3.6 | - |
| 2 | 2.2 | 4.0 | - |
| 3 | 2.2 | 5.0 | - |
| 4 | 2.8 | 2.8 | - |
| 5 | 2.8 | 3.6 | - |
| 6 | 2.8 | 4.0 | - |
| 7 | 2.8 | 5.0 | - |
| 8 | 3.6 | 3.6 | - |
| 9 | 3.6 | 4.0 | - |
| 10 | 3.6 | 5.0 | - |
| 11 | 2.2 | 2.2 | 2.2 |
| 12 | 2.2 | 2.2 | 2.8 |
| 13 | 2.2 | 2.2 | 3.6 |
| 14 | 2.2 | 2.2 | 4.0 |
| 15 | 2.2 | 2.2 | 5.0 |
| 16 | 2.2 | 2.8 | 2.8 |
| 17 | 2.2 | 2.8 | 3.6 |
| 18 | 2.2 | 2.8 | 4.0 |
| 19 | 2.8 | 2.8 | 5.0 |
| 20 | 2.2 | 3.6 | 3.6 |
| 21 | 2.2 | 3.6 | 4.0 |
| 22 | 2.8 | 2.8 | 2.8 |
| 23 | 2.8 | 2.8 | 3.6 |
| 24 | 2.8 | 2.8 | 4.0 |
| 25 | 2.8 | 3.6 | 3.6 |
| 配管限制 | ||
|---|---|---|
| 最大配管長(全長) | 50m | |
| 最大配管長(各室內-室外) | 25m | |
| 最大高低差(室內-室外) | 15m | |
| 最大高低差(室內-室內) | 10m | |
| 最小配管長(各室內-室外) | 5m | |
| 最小配管長(全長) | 15m | |
| 內含冷媒量長度 | 30m | |
| 冷媒追加填充量 | 20g/m | |
| 接續配管 | 液管徑 | ø6.35mm(2分) |
| 氣管徑 | 依照各室內機 | |
AOCG084LBTA4 (4室)
8.4kW ̶ 12.8kW 最高連結率152%
| 組合方式 | 空間1 | 空間2 | 空間3 | 空間4 |
|---|---|---|---|---|
| 1 | 2.2 | 2.2 | 4.0 | - |
| 2 | 2.2 | 2.2 | 5.0 | - |
| 3 | 2.2 | 2.2 | 6.3 | - |
| 4 | 2.2 | 2.2 | 7.1 | - |
| 5 | 2.2 | 2.8 | 3.6 | - |
| 6 | 2.2 | 2.8 | 4.0 | - |
| 7 | 2.2 | 2.8 | 5.0 | - |
| 8 | 2.2 | 2.8 | 6.3 | - |
| 9 | 2.2 | 3.6 | 3.6 | - |
| 10 | 2.2 | 3.6 | 4.0 | - |
| 11 | 2.2 | 3.6 | 5.0 | - |
| 12 | 2.2 | 3.6 | 6.3 | - |
| 13 | 2.8 | 2.8 | 2.8 | - |
| 14 | 2.8 | 2.8 | 3.6 | - |
| 15 | 2.8 | 2.8 | 4.0 | - |
| 16 | 2.8 | 2.8 | 5.0 | - |
| 17 | 2.8 | 2.8 | 6.3 | - |
| 18 | 2.8 | 3.6 | 3.6 | - |
| 19 | 2.8 | 3.6 | 4.0 | - |
| 20 | 2.8 | 3.6 | 5.0 | - |
| 21 | 2.8 | 3.6 | 6.3 | - |
| 22 | 3.6 | 3.6 | 3.6 | - |
| 23 | 3.6 | 3.6 | 4.0 | - |
| 24 | 3.6 | 3.6 | 5.0 | - |
| 25 | 2.2 | 2.2 | 2.2 | 2.2 |
| 26 | 2.2 | 2.2 | 2.2 | 2.8 |
| 27 | 2.2 | 2.2 | 2.2 | 3.6 |
| 28 | 2.2 | 2.2 | 2.2 | 4.0 |
| 29 | 2.2 | 2.2 | 2.2 | 5.0 |
| 30 | 2.2 | 2.2 | 2.8 | 2.8 |
| 31 | 2.2 | 2.2 | 2.8 | 3.6 |
| 32 | 2.2 | 2.2 | 2.8 | 4.0 |
| 33 | 2.2 | 2.2 | 3.6 | 3.6 |
| 34 | 2.2 | 2.8 | 2.8 | 2.8 |
| 35 | 2.2 | 2.8 | 2.8 | 3.6 |
| 36 | 2.8 | 2.8 | 2.8 | 2.8 |
| 37 | 2.8 | 2.8 | 2.8 | 3.6 |
| 38 | 2.8 | 2.8 | 2.8 | 4.0 |
| 39 | 2.8 | 2.8 | 3.6 | 3.6 |
| 配管限制 | ||
|---|---|---|
| 最大配管長(全長) | 70m | |
| 最大配管長(各室內-室外) | 25m | |
| 最大高低差(室內-室外) | 15m | |
| 最大高低差(室內-室內) | 10m | |
| 最小配管長(各室內-室外) | 5m | |
| 最小配管長(全長) | 20m | |
| 內含冷媒量長度 | 50m | |
| 冷媒追加填充量 | 25g/m | |
| 接續配管 | 液管徑 | ø6.35mm(2分) |
| 氣管徑 | 依照各室內機 | |
AOCG100LBTA4 (4室)
8.4kW ̶ 14.4kW 最高連結率144%
| 組合方式 | 空間1 | 空間2 | 空間3 | 空間4 |
|---|---|---|---|---|
| 1 | 5.0 | 5.0 | - | - |
| 2 | 5.0 | 6.3 | - | - |
| 3 | 6.3 | 6.3 | - | - |
| 4 | 2.2 | 2.2 | 4.0 | - |
| 5 | 2.2 | 2.2 | 5.0 | - |
| 6 | 2.2 | 2.2 | 6.3 | - |
| 7 | 2.2 | 2.2 | 7.1 | - |
| 8 | 2.2 | 2.8 | 3.6 | - |
| 9 | 2.2 | 2.8 | 4.0 | - |
| 10 | 2.2 | 2.8 | 5.0 | - |
| 11 | 2.2 | 2.8 | 6.3 | - |
| 12 | 2.2 | 3.6 | 3.6 | - |
| 13 | 2.2 | 3.6 | 4.0 | - |
| 14 | 2.2 | 3.6 | 5.0 | - |
| 15 | 2.2 | 3.6 | 6.3 | - |
| 16 | 2.8 | 2.8 | 2.8 | - |
| 17 | 2.8 | 2.8 | 3.6 | - |
| 18 | 2.8 | 2.8 | 4.0 | - |
| 19 | 2.8 | 2.8 | 5.0 | - |
| 20 | 2.8 | 2.8 | 6.3 | - |
| 21 | 2.8 | 3.6 | 3.6 | - |
| 22 | 2.8 | 3.6 | 4.0 | - |
| 23 | 2.8 | 3.6 | 5.0 | - |
| 24 | 2.8 | 3.6 | 6.3 | - |
| 25 | 3.6 | 3.6 | 3.6 | - |
| 26 | 3.6 | 3.6 | 4.0 | - |
| 27 | 3.6 | 3.6 | 5.0 | - |
| 28 | 3.6 | 3.6 | 6.3 | - |
| 29 | 3.6 | 3.6 | 7.1 | - |
| 30 | 3.6 | 5.0 | 5.0 | - |
| 31 | 2.2 | 2.2 | 2.2 | 2.2 |
| 32 | 2.2 | 2.2 | 2.2 | 2.8 |
| 33 | 2.2 | 2.2 | 2.2 | 3.6 |
| 34 | 2.2 | 2.2 | 2.2 | 4.0 |
| 35 | 2.2 | 2.2 | 2.2 | 5.0 |
| 36 | 2.2 | 2.2 | 2.2 | 6.3 |
| 37 | 2.2 | 2.2 | 2.8 | 2.8 |
| 38 | 2.2 | 2.2 | 2.8 | 3.6 |
| 39 | 2.2 | 2.2 | 2.8 | 4.0 |
| 40 | 2.2 | 2.2 | 3.6 | 3.6 |
| 41 | 2.2 | 2.8 | 2.8 | 2.8 |
| 42 | 2.2 | 2.8 | 2.8 | 3.6 |
| 43 | 2.8 | 2.8 | 2.8 | 2.8 |
| 44 | 2.8 | 2.8 | 2.8 | 3.6 |
| 45 | 2.8 | 2.8 | 2.8 | 4.0 |
| 46 | 2.8 | 2.8 | 2.8 | 5.0 |
| 47 | 2.8 | 2.8 | 3.6 | 3.6 |
| 48 | 2.8 | 2.8 | 3.6 | 4.0 |
| 49 | 2.8 | 2.8 | 3.6 | 5.0 |
| 50 | 2.8 | 2.8 | 4.0 | 4.0 |
| 51 | 2.8 | 3.6 | 3.6 | 3.6 |
| 52 | 2.8 | 3.6 | 3.6 | 4.0 |
| 53 | 3.6 | 3.6 | 4.0 | 4.0 |
| 54 | 3.6 | 3.6 | 3.6 | 3.6 |
| 配管限制 | |||
|---|---|---|---|
| 1 | 2 | ||
| 最大配管長(全長) | 40m | 70m | |
| 最大配管長(各室內-室外) | 25m | 25m | |
| 最大高低差(室內-室外) | 15m | 15m | |
| 最大高低差(室內-室內) | 10m | 10m | |
| 最小配管長(各室內-室外) | 7.5m | 5m | |
| 最小配管長(全長) | 15m | 20m | |
| 內含冷媒量長度 | 20m | 50m | |
| 冷媒追加填充量 | 25g/m | 20g/m | |
| 接續配管 | 液管徑 | ø9.52mm (3分) |
ø6.35mm (2分) |
| 氣管徑 | ø12.7mm (4分) |
依照各室內機 | |
- *
- 超過百分之百連結率,需注意使用條件。