Floor Compact & Comfort AGYG14LVCA

Indoor unit and Outdoor unit

ALL DC V-PAM
Indoor Unit :
AGYG14LVCA
Outdoor Unit :
AOYG14LVCA
Download :
Catalogue

Features

  • Outstanding energy-saving performance
  • 2-fan and wide airflow
  • Flexible and easy installation
  • Flexible pipe connection enables draining and piping in 6 directions
  • Smart device control (optional)
  • 10ºC heating operation
  • Low ambient operation

Feature Icons

Economy mode: A thermostat setting is adjusted automatically according to the room temperature to avoid unnecessary cooling or heating. 10ºC heating operation: The room temperature can be set to not go below 10°C so that the room will not become too cold when unoccupied. Auto changeover: The unit automatically switches between heating and cooling operations based on the set temperature and room temperature. Vertical swing louver: The louver automatically swings up and down. Automatic fan speed: Microprocessor automatically adjusts the fan speed and airflow according to changes in room temperature. Auto restart: The unit automatically restarts in the previous operation mode when power returns after an outage. Sleep timer: Gradually changes the room temperature to maintain a comfortable sleeping environment. Program timer: Sets the time for 1 of the following 4 options: On, Off, from On to Off, and from Off to On Filter sign: Indicates when the filter should be cleaned. Ion deodorization filter: Deodorizes the air by decomposing absorbed odors using the oxidizing and odor-reducing effects of ions generated by ultra-fine-particle ceramic. Apple-catechin filter: The Apple-catechin filter uses static electricity to remove fine particles and dust in the air. Washable panel: The front panel can be removed easily and cleaned.

Options

Setting temperature range limitation: Sets the minimum and maximum limits on room temperature to establish the right balance between energy saving and comfortable environment. Set temperature auto return: The set temperature automatically returns to the previous level. Auto-off timer: The unit automatically switches off when a predetermined time has elapsed after the timer is activated. Weekly & Temperature setback timer: Sets temperature for two sets of On/Off times and for each day of the week. External On/Off input

Capacity

Cooling  4.2 kW
Heating  5.2 kW


Specifications

Power Source Phase Single-phase
Voltage 230 V
Frequency 50 Hz
Capacity Cooling 4.2 kW(0.9 - 5.0) kW
Heating 5.2 kW (0.9 - 8.0) kW
Input Power Cooling 1.14 kW
Heating 1.44 kW
EER Cooling 3.68 W/W
COP Heating 3.61 W/W
Pdesign Cooling 4.2 kW
Heating (-10°C) 4.7 kW
SEER Cooling 6.40 W/W
SCOP Heating (Average) 4.00 W/W
Energy Efficiency Class Cooling A++
Heating A+
Max. Operating Current Cooling 9.0 A
Heating 13.5 A
Annual Energy Consumption Cooling 230 kWh/a
Heating 1635 kWh/a
Moisture Removal 2.1 I/h
Sound Pressure Level*2 Indoor (Cooling) High 44 dB(A)
Middle 38 dB(A)
Low 31 dB(A)
Quiet 22 dB(A)
Indoor (Heating) High 43 dB(A)
Middle 37 dB(A)
Low 29 dB(A)
Quiet 22 dB(A)
Sound Pressure Level*2 Outdoor (Cooling) High 50 dB(A)
Outdoor (Heating) High 50 dB(A)
Sound Power Level Indoor (Cooling) High 58 dB(A)
Indoor (Heating) High 58 dB(A)
Outdoor (Cooling) High 65 dB(A)
Outdoor (Heating) High 66 dB(A)
Airflow Rate Indoor High 650 m3/h
Outdoor High 1910 m3/h
Net Dimensions
Indoor
Height 600 mm
Width 740 mm
Depth 200 mm
Net Dimensions
Outdoor
Height 578 mm
Width 790 mm
Depth 300 mm
Net Weight Indoor 14 kg (31 lbs)
Outdoor 40 kg (88 lbs)
Connection Pipe Diameter Liquid 6.35 mm
Gas 12.7 mm
Drain Hose Diameter Indoor 13.8 mm
Outdoor 15.8 to 16.7 mm
Max. Pipe Length (Pre Charge) 20 (15) m
Max. Height Difference 15 m
Operation Range Cooling -10 to 43 °C DB
Heating -15 to 24 °C DB
Refrigerant Type R410A
Global Warming Potential 2,088
Charge 1,150 g
Scroll

Dimensions

Indoor Unit : AGYG14LVCA

Indoor unit

Optional Parts

Wired Remote Controller
UTY-RVNYM
Simple Remote Controller
UTY-RSNYM
Half Concealed Kit
UTR-STA