EMC Test Service for LED Luminaries
LED luminaries are subject to control of Electrical Appliances and Materials Safety Law since July 2012, must to measure EMI of it now. We do radiated power measurement and conducted noise measurement for home appliance ever before.
We had expanded our facility for radiated power before this control of Ministerial Order Cluse1 Standard lunched and introduced the large loop antenna for magnetic field noise measurement which requested by Ministerial Order Cluse2 Standard (J55015) and Europe(EN55015). We had approved "S-Mark" by TÜV Rheinland and started these measurement services. We are offering every necessary test services which requested by CE mark including immunity demand in case for Europe.
Test Specifications
Destination | Regulation | Standard | Entry | Description |
---|---|---|---|---|
Japan | EMI (PSE Mark) | Ministerial Order Cluse1 Standard* (Noise Strongnesse) |
Conducted Noise | 526.5kHz - 30MHz, AMN |
Radiated Power | 30 - 300MHz, EMI Clump | |||
Ministerial Order Cluse2 Standard* (J55015) |
Conducted Noise | 150kHz - 30MHz, AMN | ||
Magnetic Field Noise | 150kHz - 30MHz, Large Loop Antenna | |||
Radiated Power | 30 - 300MHz, EMI Clump | |||
Harmonics current | JIS C61000-3-2 | Harmonic Current | Class C | |
Europe (CE Mark) |
EMI | EN55015 | Conducted Noise | 9kHz - 30MHz, AMN |
Magnetic Field Noise | 150kHz - 30MHz, Large Loop Antenna | |||
Radiated Noise | 30~300MHz, 10m RF Chamber | |||
Immunity | EN61547 | ESD | Contact ±4kV, non-contact ±8kV | |
Radiated Immunity | 80 - 1,000MHz, 3V/m, 80%AM | |||
EFT / Burst | AC±1.0kV, DC±0.5kV, Signal±0.5kV | |||
Thunder Surge (AC Power) |
≤25W:L-PE±1.0kV, L-L±0.5kV >25W:L-PE±2.0kV, L-L±1.0kV |
|||
Conducted Immunity | 150kHz - 80MHz, 3Vrms, 80%AM | |||
Power Freq Magnetic Field | 50/60Hz, 3A/m | |||
Dip/Interruption | 70%/10cycle, 0%/0.5cycle | |||
Harmonic current | EN61000-3-2 | Harmonic current | Class C | |
Voltage Fluctuation / Flicker |
EN61000-3-3 | Voltage Fluctuation / Flicker |
* Client may choose to test with Ministerial Order Cluse1 or 2.
Radiated Power Measurement Equipment
* Introduction EMI Clump and Positioner in addition, two chambers are available for measurement now!!
Radiated Noise Measurement
(10M Method RF Chamber)
Large Loop Antenna
Support Service for "S-Mark" Certification
One-Stop Service is now available from apply to certificate for "S-Mark" by TÜV Rheinland at our Laboratory.
* Your order can be done to us directly or thru TÜV Rheinland.