EMC Test Service for LED Luminaries

LED luminaries are subject to control of Electrical Appliances and Materials Safety Law since July 2012, must to measure EMI of it now. We do radiated power measurement and conducted noise measurement for home appliance ever before.

We had expanded our facility for radiated power before this control of Ministerial Order Cluse1 Standard lunched and introduced the large loop antenna for magnetic field noise measurement which requested by Ministerial Order Cluse2 Standard (J55015) and Europe(EN55015). We had approved "S-Mark" by TÜV Rheinland and started these measurement services. We are offering every necessary test services which requested by CE mark including immunity demand in case for Europe.

Test Specifications

Destination Regulation Standard Entry Description
Japan EMI (PSE Mark) Ministerial Order Cluse1 Standard*
(Noise Strongnesse)
Conducted Noise 526.5kHz - 30MHz, AMN
Radiated Power 30 - 300MHz, EMI Clump
Ministerial Order Cluse2 Standard*
(J55015)
Conducted Noise 150kHz - 30MHz, AMN
Magnetic Field Noise 150kHz - 30MHz, Large Loop Antenna
Radiated Power 30 - 300MHz, EMI Clump
Harmonics current JIS C61000-3-2 Harmonic Current Class C
Europe
(CE Mark)
EMI EN55015 Conducted Noise 9kHz - 30MHz, AMN
Magnetic Field Noise 150kHz - 30MHz, Large Loop Antenna
Radiated Noise 30~300MHz, 10m RF Chamber
Immunity EN61547 ESD Contact ±4kV, non-contact ±8kV
Radiated Immunity 80 - 1,000MHz, 3V/m, 80%AM
EFT / Burst AC±1.0kV, DC±0.5kV, Signal±0.5kV
Thunder Surge
(AC Power)
≤25W:L-PE±1.0kV, L-L±0.5kV
>25W:L-PE±2.0kV, L-L±1.0kV
Conducted Immunity 150kHz - 80MHz, 3Vrms, 80%AM
Power Freq Magnetic Field 50/60Hz, 3A/m
Dip/Interruption 70%/10cycle, 0%/0.5cycle
Harmonic current EN61000-3-2 Harmonic current Class C
Voltage Fluctuation
/ Flicker
EN61000-3-3 Voltage Fluctuation
/ Flicker
 

*   Client may choose to test with Ministerial Order Cluse1 or 2.

Radiated Power Measurement Equipment

Photo : Large Shield Room.

* Introduction EMI Clump and Positioner in addition, two chambers are available for measurement now!!

Radiated Noise Measurement
(10M Method RF Chamber)

Photo : 10m method RF semi-anechoic chamber.

Large Loop Antenna
 

Photo : Large Loop Antenna.


Support Service for "S-Mark" Certification

One-Stop Service is now available from apply to certificate for "S-Mark" by TÜV Rheinland at our Laboratory.

* Your order can be done to us directly or thru TÜV Rheinland.

Image : Support Service for "S-Mark" Certification FlowImage : TÜV Logo

 