Features

  • Highly efficient, compact design
  • More comfortable airflow
  • Powerful operation
  • 10ºC heating operation
  • Low noise mode for outdoor unit
  • Low ambient operation

Feature Icons

Economy mode: A thermostat setting is adjusted automatically according to the room temperature to avoid unnecessary cooling or heating. Power diffuser: An additional louver that opens based on input from monitoring sensors to quickly enhance immediate comfort needs. Powerful mode: The air conditioner operates at the maximum airflow level and compressor speed to cool or warm the room quickly. 10ºC heating operation: The room temperature can be set to not go below 10°C so that the room will not become too cold when unoccupied. Low noise mode: Reduces the noise level of an outdoor unit. Auto changeover: The unit automatically switches between heating and cooling modes based on the temperature setting and the room temperature. Vertical swing louver: The louver automatically swings up and down. Automatic fan speed: A micro-computer automatically adjusts the airflow to follow the changes in room temperature. Auto restart: In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored. Sleep timer: A micro-computer gradually changes the room temperature automatically to promote a comfortable night's sleep. Program timer: This digital timer allows selection of one of four options: ON, OFF, ON » OFF, or OFF » ON. Filter sign: Indicates the filter cleaning period by blinking. Ion deodorization filter: The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by an ultra-fine-particle ceramic. Apple-catechin filter: The Apple-catechin filter uses static electricity to clean fine particles and dust from the air. Washable panel: Since the front panel is easy to remove, maintenance is also easy.

Options

Setting temperature range limitation: Sets the minimum and maximum limits on room temperature to establish the right balance between energy saving and a comfortable environment. Set temperature auto return: The setting temperature automatically returns to the previously set temperature. Auto-off timer: Automatically stops operation when a fixed time has elapsed from the start of operation. Weekly & Temperature setback timer: Weekly & Temperature setback timer can set the temperature for 2-time spans and for each day of the week. External error output External ON/OFF input Special Cooling: Special Cooling

Capacity

Cooling  4.0 kW
Heating  5.0 kW


Specifications

Power Source Phase Single phase
Voltage 230 V
Frequency 50 Hz
Capacity Cooling 4.0 kW(0.9 - 4.4) kW
Heating 5.0 kW (0.9 - 6.0) kW
Input Power Cooling 1.135 kW
Heating 1.365 kW
EER Cooling 3.52 W/W
COP Heating 3.66 W/W
Pdesign Cooling 4.0 kW
Heating (-10°C) 3.9 kW
SEER Cooling 6.90 W/W
SCOP Heating (Average) 4.00 W/W
Energy Efficiency Class Cooling A++
Heating A+
Max. Operating Current Cooling 9.0 A
Heating 10.5 A
Annual Energy Consumption Cooling 203 kWh/a
Heating 1365 kWh/a
Moisture Removal 2.1 I/h
Sound Pressure Level*2 Indoor (Cooling) High 44 dB(A)
Middle 40 dB(A)
Low 33 dB(A)
Quiet 25 dB(A)
Indoor (Heating) High 44 dB(A)
Middle 40 dB(A)
Low 35 dB(A)
Quiet 27 dB(A)
Sound Pressure Level*2 Outdoor (Cooling) High 50 dB(A)
Outdoor (Heating) High 50 dB(A)
Sound Power Level Indoor (Cooling) High 60 dB(A)
Indoor (Heating) High 60 dB(A)
Outdoor (Cooling) High 65 dB(A)
Outdoor (Heating) High 65 dB(A)
Airflow Rate Indoor High 750 m3/h
Outdoor High 1800 m3/h
Net Dimensions
Indoor
Height 268 mm
Width 840 mm
Depth 203 mm
Net Dimensions
Outdoor
Height 540 mm
Width 790 mm
Depth 290 mm
Net Weight Indoor 8.5 kg (19 lbs)
Outdoor 34 kg (75 lbs)
Connection Pipe Diameter Liquid 6.35 mm
Gas 12.7 mm
Drain Hose Diameter Indoor 13.8 mm
Outdoor 15.8 to 16.7 mm
Max. Pipe Length (Pre Charge) 20 (15) m
Max. Height Difference 15 m
Operation Range Cooling -10 to 43 °C DB
Heating -15 to 24 °C DB
Refrigerant Type R410A
Global Warming Potential 2,088
Charge 1,050 g
Scroll

Dimensions

Indoor Unit : ASHG14LMCA

Indoor unit

Optional Parts

Wired Remote Controller
UTY-RNNGM
Wired Remote Controller
UTY-RVNGM
Simple Remote Controller
UTY-RSNGM
Communication kits