4 Rooms Multi

AOGG30LAT4

Features

Combination Table

Dimentions

Specification


AOGG30LAT4 Outndoor Unit

ALL DC

Ticks4

  • Comfortable space that matches your lifestyle
  • Wide range of indoor units with various models
  • Top class energy saving
  • Outdoor unit's space saving design makes for a better looking exterior

 

Specifications

Operation Mode Cooling Heating
Rated Capacity (min-max) 8.0(3.5~10.1)kW 9.6(3.7~12.0)kW
Operation Range 10~46°CDB -10~24°CDB
Sound pressure level 50dB(A) 51dB(A)
Unit  
Net Dimension (H×W×D) 830×900×330mm
Weight 68kg(149.9lbs)
Connection pipe  
Piping Connections Small(Liquid) ø6.35x4mm
(*ø6.35x3, ø9.52mm)
Piping Connections Large(Gas) ø9.52x2, ø12.7x2mm
Max. length (Total/Each) 70/25m
Max Height Difference
Between Outdoor Unit and Each Indoor Units.
15m
Max Height Difference
Between Indoor Units.
10m
System Data  
Power Source 230V/1φ/50Hz
Refrigerant R410A

Note : Specifications are based on the following conditions.

  • Cooling: Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CWB.
  • Heating: Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
  • Pipe length: 5m, Height difference: 0m. (Outdoor unit - indoor unit)

Dimensions

Outdoor Dimensions

Combination Table

Combination
of indoor unit
Room 1 Room 2 Room 3 Room 4 Total
1 Room 7 - - - 7
9 - - - 9
12 - - - 12
14 - - - 14
18 - - - 18
24 - - - 24
2 Room 7 7 - - 14
7 9 - - 16
7 12 - - 19
7 14 - - 21
7 18 - - 25
7 24 - - 31
9 9 - - 18
9 12 - - 21
9 14 - - 23
9 18 - - 27
9 24 - - 33
12 12 - - 24
12 14 - - 26
12 18 - - 30
12 24 - - 36
14 14 - - 28
14 18 - - 32
14 24 - - 38
18 18 - - 36
18 24 - - 42
3 Room 7 7 7 - 21
7 7 9 - 23
7 7 12 - 26
7 7 14 - 28
7 7 18 - 32
7 7 24 - 38
7 9 9 - 25
7 9 12 - 28
7 9 14 - 30
7 9 18 - 34
7 9 24 - 40
7 12 12 - 31
7 12 14 - 33
7 12 18 - 37
7 12 24 - 43
7 14 14 - 35
7 14 18 - 39
7 14 24 - 45
7 18 18 - 43
7 18 24 - 49
9 9 9 - 27
9 9 12 - 30
9 9 14 - 32
9 9 18 - 36
9 9 24 - 42
9 12 12 - 33
9 12 14 - 35
9 12 18 - 39
9 12 24 - 45
9 14 14 - 37
9 14 18 - 41
9 14 24 - 47
9 18 18 - 45
12 12 12 - 36
12 12 14 - 38
12 12 18 - 42
12 12 24 - 48
12 14 14 - 40
12 14 18 - 44
12 18 18 - 48
4 Room 7 7 7 7 28
7 7 7 9 30
7 7 7 12 33
7 7 7 14 35
7 7 7 18 39
7 7 9 9 32
7 7 9 12 35
7 7 9 14 37
7 7 9 18 41
7 7 12 12 38
7 7 12 14 40
7 7 12 18 41
7 7 14 14 42
7 7 14 18 46
7 9 9 9 34
7 9 9 12 37
7 9 9 14 39
7 9 9 18 43
7 9 12 12 40
7 9 12 14 42
7 9 12 18 46
7 9 14 14 44
7 9 14 18 48
7 12 12 12 43
7 12 12 14 45
7 12 12 18 49
7 12 14 14 47
9 9 9 9 36
9 9 9 12 39
9 9 9 14 41
9 9 9 18 45 *¹
9 9 12 12 42
9 9 12 14 44
9 9 12 18 48 *²
9 9 14 14 46
9 12 12 12 45
9 12 12 14 47
9 12 14 14 49
12 12 12 12 48

Note :

  • 7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models
  • Operating data under running indoor units are shown on the above table.
  • 3 or more indoor units should be connected.
  • Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit)
  • The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu.
  • *1 : Connection of ASGG18L + ARGG09L + ARGG09L + ARGG09L is not available. All types other than this combination can be connected.
    *2 : Connection of ASGG18L + ARGG12L + ARGG09L + ARGG09L is not available. All types other than this combination can be connected.

Related Links