2 Rooms Multi

AOGG18LAC2

Features

Combination Table

Dimentions

Specification


AOGG18LAC2 Outndoor Unit

ALL DC

Ticks4

  • Comfortable space that matches your lifestyle
  • Wide range of indoor units with various models
  • Top class energy saving
  • Outdoor unit's space saving design makes for a better looking exterior

 

Specifications

Operation Mode Cooling Heating
Rated Capacity (min-max) 5.0(1.7~5.6)kW 5.6(1.8~6.1)kW
Operation Range 10~46°CDB -10~24°CDB
Sound pressure level 51dB(A) 51dB(A)
Unit  
Net Dimension ( H×W×D) 540×790×290mm
Weight 38kg(83.8lbs)
Connection pipe  
Piping Connections Small(Liquid) ø6.35×2mm
Piping Connections Large(Gas) ø9.52×2mm
Max. length (Total/Each) 30/20m
Max Height Difference
Between Outdoor Unit and Each Indoor Units.
15m
Max Height Difference
Between Indoor Units.
10m
System Data  
Power Source 230V/1φ/50Hz
Refrigerant R410A

Note : Specifications are based on the following conditions.

  • Cooling: Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CWB.
  • Heating: Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
  • Pipe length: 5m, Height difference: 0m. (Outdoor unit - indoor unit)

Dimensions

Outdoor Dimensions

Combination Table

Combination
of indoor unit
Room 1 Room 2 Total
1 Room 7 - 7
9 - 9
12 - 12
2 Room 7 7 14
7 9 16
7 12 19
9 9 18
9 12 21
12 12 24

Note :

  • 7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models
  • Operating data under running indoor units are shown on the above table.
  • 2 or more indoor units should be connected.
  • Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit)
  • The Total ability of connected a indoor unit is up to 21000Btu from 14000Btu.