Wall Mounted Standard Range Comfort for Large Room ASYG18LFCA
Features
- “Vertical airflow” provides powerful floor level heating
- “Horizontal airflow” does not blow cool air directly at the occupants in the room
- Air conditioner filter features
- Flexible Installation
- Low ambient operation
Capacity


Specification
Power source | Phase | Single-phase | |
---|---|---|---|
Voltage | 230 V | ||
Frequency | 50 Hz | ||
Capacity | Cooling | 5.2 kW(0.9 - 6.0) kW | Heating | 6.3 kW (0.9 - 9.1) kW |
Input Power | Cooling | 1.52 kW | |
Heating | 1.71 kW | ||
COP | Heating | 3.68 W/W | |
Pdesign | Cooling | 5.2 kW | |
Heating (-10°C) | 5.9 kW | ||
SEER | Cooling | 6.94 W/W | |
SCOP | Heating (Average) | 3.87 W/W | |
Energy Efficiency Class | Cooling | A+ | |
Heating | A | ||
Max. Operating Current | Cooling | 9.0 A | |
Heating | 12.5 A | ||
Annual Energy Consumption | Cooling | 262 kWh/a | |
Heating | 2130 kWh/a | ||
Moisture Removal | 2.6 I/h | ||
Sound Pressure Level | Indoor (Cooling) | High | 43 dB(A) |
Middle | 37 dB(A) | ||
Low | 33 dB(A) | ||
Quiet | 26 dB(A) | ||
Indoor (Heating) | High | 42 dB(A) | |
Middle | 37 dB(A) | ||
Low | 33 dB(A) | ||
Quiet | 25 dB(A) | ||
Sound Pressure Level | Outdoor (Cooling) | High | 50 dB(A) |
Outdoor (Heating) | High | 51 dB(A) | |
Sound Power Level | Indoor (Cooling) | High | 58 dB(A) |
Indoor (Heating) | High | 58 dB(A) | |
Outdoor (Cooling) | High | 65 dB(A) | |
Outdoor (Heating) | High | - dB(A) | |
Air Flow Rate | Indoor | High | 900 m3/h |
Outdoor | High | 2150 m3/h | |
Net Dimensions Indoor |
Height | 320 mm | |
Width | 998 mm | ||
Depth | 238 mm | ||
Net Dimensions Outdoor |
Height | 620 mm | |
Width | 790 mm | ||
Depth | 290 mm | ||
Net Weight | Indoor | 14 kg (31 lbs) | |
Outdoor | 41 kg (90 lbs) | ||
Connection Pipe Diameter | Liquid | 6.35 mm | |
Gas | 12.7 mm | ||
Drain Hose Diameter | Indoor | 12 mm | |
Outdoor | 16 mm | ||
Max Pipe Length (Pre Charge) | 25 (15) m | ||
Max Height Difference | 20 m | ||
Operation Range | Cooling | -10 to 46 °CDB | |
Heating | -15 to 24 °CDB | ||
Refrigerant | Type | R410A | |
Global Warming Potential | 2,088 | ||
Charge | 1,200 g |
Scroll
Dimensions
Indoor Unit : ASYG18LFCA
Optional Parts
- Wired Remote Controller
- UTY-RNNYM
- Wired Remote Controller
- UTY-RVNYM
- Simple Remote Controller
- UTY-RSNYM