Ceiling Comfort for Large Rooms ABYG45LRTA  [3Phase]

Indoor unit and Outdoor unit

ALL DC
Indoor Unit :
ABYG45LRTA
Outdoor Unit :
AOYG45LATT
Download :
Catalogue

Features

  • Flexible installation
  • Multi auto swing
  • Fresh air intake
  • Low ambient operation

Feature Icons

Economy mode: A thermostat setting is adjusted automatically according to the room temperature to avoid unnecessary cooling or heating. 10ºC heating operation: The room temperature can be set to not go below 10°C so that the room will not become too cold when unoccupied. Auto changeover: The unit automatically switches between heating and cooling modes based on the temperature setting and the room temperature. Automatic double swings: Activates complex swing action of the louver in both horizontal and vertical directions. Automatic fan speed: A micro-computer automatically adjusts the airflow to follow the changes in room temperature. Auto restart: In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored. Connectable fresh air duct: Outside air can be introduced by attaching a locally purchased duct to the fresh air knockout and an optional part. Sleep timer: A micro-computer gradually changes the room temperature automatically to promote a comfortable night's sleep. Program timer: This digital timer allows selection of one of four options: ON, OFF, ON » OFF, or OFF » ON. Filter sign: Indicates the filter cleaning period by blinking. Blue fin

Options

Setting temperature range limitation: Sets the minimum and maximum limits on room temperature to establish the right balance between energy saving and a comfortable environment. Set temperature auto return: The setting temperature automatically returns to the previously set temperature. Low noise mode: Reduces the noise level of an outdoor unit. Fresh air intake: Fresh air can be taken in by a fan connected to an external control unit. Auto-off timer: Automatically stops operation when a fixed time has elapsed from the start of operation. Weekly & Temperature setback timer: Weekly & Temperature setback timer can set the temperature for 2-time spans and for each day of the week. External ON/OFF input Special Cooling: Special Cooling

Capacity

Cooling  12.5 kW
Heating  14.0 kW


Specifications

Power Source Phase 3-phase
Voltage 400 V
Frequency 50 Hz
Capacity Cooling 12.5 kW(5.0 - 14.0) kW
Heating 14.0 kW (5.4 - 16.2) kW
Input Power Cooling 3.89 kW
Heating 3.88 kW
EER Cooling 3.21 W/W
COP Heating 3.61 W/W
Pdesign Cooling - kW
Heating (-10°C) - kW
SEER Cooling - W/W
SCOP Heating (Average) - W/W
Energy Efficiency Class Cooling -
Heating -
Max. Operating Current Cooling 8.9 A
Heating 8.9 A
Annual Energy Consumption Cooling - kWh/a
Heating - kWh/a
Moisture Removal 4.5 I/h
Sound Pressure Level*2 Indoor (Cooling) High 49 dB(A)
Middle 45 dB(A)
Low 39 dB(A)
Quiet 34 dB(A)
Indoor (Heating) High 49 dB(A)
Middle 45 dB(A)
Low 39 dB(A)
Quiet 34 dB(A)
Sound Pressure Level*2 Outdoor (Cooling) High 54 dB(A)
Outdoor (Heating) High 54 dB(A)
Sound Power Level Indoor (Cooling) High - dB(A)
Indoor (Heating) High - dB(A)
Outdoor (Cooling) High - dB(A)
Outdoor (Heating) High - dB(A)
Airflow Rate Indoor High 2100 m3/h
Outdoor High 6900 m3/h
Net Dimensions
Indoor
Height 240 mm
Width 1660 mm
Depth 700 mm
Net Dimensions
Outdoor
Height 1290 mm
Width 900 mm
Depth 330 mm
Net Weight Indoor 46 kg (101 lbs)
Outdoor 104 kg (229 lbs)
Connection Pipe Diameter Liquid 9.52 mm
Gas 15.88 mm
Drain Hose Diameter Indoor 22.0 mm
Outdoor 25.6 mm
Max. Pipe Length (Pre Charge) 75 (30) m
Max. Height Difference 30 m
Operation Range Cooling -15 to 46 °C DB
Heating -15 to 24 °C DB
Refrigerant Type R410A
Global Warming Potential 2,088
Charge 3,450 g
Scroll

Dimensions

Indoor Unit : ABYG45LRTA

Indoor unit

Optional Parts

Wired Remote Controller
UTY-RVNYM
Simple Remote Controller
UTY-RSNYM
Drain Pump Unit
UTR-DPB24T
Flange
UTD-RF204 (Round)