Split type High Power Series WSYG140DG6 / WOYG112LCTA
Features
- High leaving water temperature
- High COP
- 2 Zone individual control
- Automatic heating curve control
- High durability
- Emergency operation
Specification
Capacity range | 11 | |
---|---|---|
7°C/35°C floor heating *1 | Heating capacity | 10.80 kW |
Input Power | 2.54 kW | |
COP | 4.25 | |
2°C/35°C floor heating *1 | Heating capacity | 10.77 kW |
Input Power | 3.44 kW | |
COP | 3.13 | |
-7°C/35°C floor heating *1 | Heating capacity | 10.38 kW |
Input Power | 4.32 kW | |
COP | 2.4 |
Scroll
Space heating characteristics *2
Temperature application | 55 °C | 35 °C | |
---|---|---|---|
Energy Efficiency Class | A+ | A++ | |
Rated heat output | 9 kW | 11 kW | |
Seasonal space heating energy efficiency (ηs) | 109 % | 151 % | |
Annual energy consumption | 6842 kWh | 6062 kWh | |
Sound Power Level | Hydraulic indoor unit | 46 dB(A) | |
Outdoor unit | 68 dB(A) |
Scroll
Hydraulic indoor unit Specification
Power source | Phase | 1 ø |
---|---|---|
Voltage | 230 V | |
Frequency | 50 Hz | |
Net Dimensions | Height | 800 mm |
Width | 450 mm | |
Depth | 457 mm | |
Net Weight | 42 kg | |
Water circulation | Min/Max | 19.5 / 39.0 L/min |
Buffer tank capacity | 16 L | |
Expansion vessel capacity | 8 L | |
Leaving water temperature range | Max | 60 °C |
Water pipe connection diameter | Flow | Ø 25.4 mm |
Return | Ø 25.4 mm | |
Backup heater | Capacity | 6.0 (3.0kW×2pcs.) kW |
Scroll
Outdoor unit specification
Power source | Phase | 1 ø |
---|---|---|
Voltage | 230 V | |
Frequency | 50 Hz | |
Current | Max | 22.0 A |
Net Dimensions | Height | 1,290 mm |
Width | 900 mm | |
Depth | 330 mm | |
Net Weight | 92 kg | |
Refrigerant (Global Warming Potential) | R410A (2,088) | |
Refrigerant amount | 2.50 kg | |
Additional refrigerant charge amount | 50 g/m | |
Connection Pipe Diameter | Liquid | Ø 9.52 mm |
Gas | Ø 15.88 mm | |
Pipe Length | Min/Max | 5 / 20 m |
Pre Charge | 15 m | |
Height Difference | Max | 15 m |
Operation Range | Heating | -25 to 35 °C |
Scroll
Dimensions
Hydraulic Unit : WSYG140DG6
Outdoor Unit : WOYG112LCTA
Optional Parts
- 2nd Circuit Kit
- UTW-KZSXE
- Boiler Connection kit
- UTW-KBSXD
- Balancing vessel
- UTW-TEVXA
- DHW kit
- UTW-KDWXD (External)
- DHW tank
- UTW-T20XA (200 Liter)
- DHW tank
- UTW-T30XA (300 Liter)
- DHW tank
- UTW-T30XD (300 Liter)
- Circulating pump
- UTW-PHFXD
- Swimming Pool kit
- UTW-KSPXD
- Heat Exchanger for swimming pool kit
- UTW-ESPXA
- Cooling kit
- UTW-KCLXD
- Regulation Extension Kit
- UTW-KREXD
- Low Noize Kit
- UTW-KLNXE
- Cascade Master Kit (incl. LPB Clip)
- UTW-KCMXE
- Cascade Slave Kit (incl. LPB Clip)
- UTW-KCSXE
- HMI Kit
- UTW-KHMXE
- Remote Controller
- UTW-C74TXF
- Remote Controller
- UTW-C74HXF
- Remote Controller
- UTW-C78XD
- Remote Controller
- UTW-C78XD-E
- Room Themostat
- UTW-C55XA
- Room Themostat
- UTW-C58XD
- Outdoor Sensor Transmitter
- UTW-MOSXD
- RF Modules
- UTW-MRCXD
- Web server
- UTW-KW1XD
- Web server
- UTW-KW4XD
- LPB Clip
- UTW-KL1XD
- Modbus Clip
- UTW-KMBXE
- Base Heater
- UTW-HAMXE
- Base Heater
- UTW-HAMXF
- Service Tool (incl. OCI700 adaptor)
- UTW-KSTXD
- Service Tool Software
- UTW-KPSXD
- External connect kit
- UTY-XWZXZ2
- UTW-KHMXE,UTW-C74TXF,UTW-C74HXF :
- 19 Languages included,no separate Estern European RC necessary. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
- UTW-C78XD-E :
- Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
- UTW-KSTXD :
- UTW-KL1XD is required for the connection.
- UTW-KPSXD :
- UTW-KW1XD or UTW-KW4XD is required for the connection.
- UTW-KMBXE :
- Additional optional part necessary