Main contents starts here.
Introduction of laboratory
External view of EMC site

Layout of EMC site and test equipments.
1st floor

2nd floor

3rd floor

Measurement and Test Facility
1st 10m method RF semi-anechoic chamber

- High performance 10m method RF semi-anechoic chamber neither the outpatient electric wave nor the weather are controlled.
- High speed (four times against open site) and highly accurate automatic operation measurements of radiation noise.
- Site attenuation: within ±3dB
- Radiation noise measurement: 30Hz to 40GHz
- Field uniformity: 0db-6db (80MHz-2700MHz)
- Turntable: φ5m/ 3ton
- Carrying door: 2.5m × 2.5m
- Power supply capacity: 36KVA
2nd 10m method RF semi-anechoic chamber

- Site attenuation: within ±3dB
- Radiation noise measurement: 30Hz to 40GHz
- Field uniformity: 0db-6db (80MHz-2700MHz)
- Turntable: φ4m/ 2ton
- Carrying door: 2.0m × 1.5m
- Power supply capacity: 12KVA
Full anechoic small chamber (six ferrite wall and low frequency magnetic shield)

- Radiation immunity test: 10kHz-18GHz
- Field uniformity: 0dB-6dB (80MHz-2700MHz)
- MIL-461F test
- Electromagnetic super-low frequency field measurement: 1Hz-400kHz
- Residual magnetic field: AC 0.02mG or less (1/30 on outdoor)
2nd small electric wave chamber

- Radiation immunity test: 10kHz to 18GHz
- CISPR25 Compiant test: For "Category5" measurements
- MIL-461F test
- Automotive equipment test (e-mark and manufacturer standard)
Shield room (3)

- Changeability at each temperature and humidity: (10-40°C, 20-90%RH)
- Radiated power/ conduction noise measurement for consumer electric equipment
- CVCF : 36KVA
Dip/ Instantaneous interruption

1φ/ 3φ, 100-480V, 50A/aspect
Thunder surge
G-TEM cell

The immunity test of DC-18GHz, 200V/m