Airstage™ (VRF Systems) V-II Series
Features
Common Features
- High Energy Efficiency
- Energy Saving Function
- More Comfort
- Design Flexibility
- High Reliability
- Easy Installation
- Easy Service & Maintenance
Series Features
Outdoor units lineup
| Space saving combination | Energy efficiency combination | |
|---|---|---|
| 8 HP | AJYA72LALH | |
| 10 HP | AJYA90LALH | |
| 12 HP | AJY108LALH | |
| 14 HP | AJY126LALH | |
| 16 HP | AJY144LALH | AJY144LALHH |
| 18 HP | AJY162LALH | |
| 20 HP | AJY180LALH | |
| 22 HP | AJY198LALH | AJY198LALHH |
| 24 HP | AJY216LALH | AJY216LALHH |
| 26 HP | AJY234LALH | AJY234LALHH |
| 28 HP | AJY252LALH | AJY252LALHH |
| 30 HP | AJY270LALH | AJY270LALHH |
| 32 HP | AJY288LALH | AJY288LALHH |
| 34 HP | AJY306LALH | AJY306LALHH |
| 36 HP | AJY324LALH | AJY324LALHH |
| 38 HP | AJY342LALH | |
| 40 HP | AJY360LALH | AJY360LALHH |
| 42 HP | AJY378LALH | AJY378LALHH |
| 44 HP | AJY396LALH | AJY396LALHH |
| 46 HP | AJY414LALH | |
| 48 HP | AJY432LALH |
System Outline
Excellent energy saving
Heat pump type inverter control is used to achieve economic cooling and heating operation for individual air conditioning to entire air conditioning.
High design flexibility for various building air conditioning
The high static pressure design flexibly meets the needs of high rise buildings including easy installation on each floor.
Easy installation and maintenance
The flexible communication method and piping connections makes installation and maintenance easy even for large systems.
Features
Efficiency in actual operation
Top class high COP is achieved for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and our own technologies.
Space saving combination
Energy efficiency combination
For 24 HP Combination
Energy saving technology that boosted operation efficiency
Powerful large propeller fan
By using CFD*1 technology, a newly designed fan achieves high performance and low noise operation.
- *1.
- CFD = Computational Fluid Dynamics
3 phase DC fan motor
Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is realized by DC fan motor.
Subcool heat exchanger
High Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction.
Sine-wave DC inverter control
High efficiency is realized by adoption of reduced switching loss IPM.
High efficient and large capacity DC inverter compressor
Large capacity high efficient DC twin rotary compressor with excellent intermediate capability.
4-face heat exchanger
Heat exchange efficiency is significantly improved by the introduction of a new 4-face heat exchanger that increases effective surface area.
Front intake port (corner cut air inhaling structure)
In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger.




