Medium Static Pressure Duct High Efficiency & Comfort ARYG45LMLA

Indoor unit and Outdoor unit

ALL DC i-PAM
Indoor Unit :
ARYG45LMLA
Outdoor Unit :
AOYG45LETL
Download :
Catalogue

Features

  • Slim & Compact design
  • Two-direction drain piping
  • Easy maintenance
  • Low ambient operation

Feature Explanation Icons

Economy mode : Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating. Auto-changeover : The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature. Automatic fan speed : The micro-computer automatically adjusts the airflow effectively to follow the changes of room temperature. Auto restart : In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once power supply is restored. Connectable fresh air duct : Outside air can be introduced by attaching field supplied duct to fresh air knockout and optional part. Connectable distributing duct : Systems are capable of attaching field-supplied branch ducts distributing the airflow. Weekly + setback timer : Weekly + Setback timer can set temperature for two times spans and for each day of the week. Filter sign : Indicates the filter cleaning period by lamp.

Options

Room temperature set point limitation : The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants. Set temperature auto return : The setting temperature automatically returns to the previously set temperature. 10°C HEAT operation : The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied. Fresh air intake : Fresh air can be taken in by a fan which can be connected using external control unit. Auto off timer : Automatically stops operation when a fixed time has elapsed from the start of operation. Sleep timer : The micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep. Program timer : This digital timer allows selection of one of four options : ON, OFF, ON;→OFF or OFF→ON. External ON/OFF input

Capacity

Cooling  12.1 kW
Heating  13.1 kW


Specification

Power source Phase Single-phase
Voltage 230 V
Frequency 50 Hz
Capacity Cooling 12.1 kW(4.0 - 13.3) kW
Heating 13.1 kW (4.2 - 15.5) kW
Input Power Cooling 3.77 kW
Heating 3.68 kW
COP Heating 3.61 W/W
Pdesign Cooling - kW
Heating (-10°C) - kW
SEER Cooling - W/W
SCOP Heating (Average) - W/W
Energy Efficiency Class Cooling -
Heating -
Max. Operating Current Cooling 21.0 A
Heating 21.0 A
Annual Energy Consumption Cooling - kWh/a
Heating - kWh/a
Moisture Removal 4.0 I/h
Sound Pressure Level Indoor (Cooling) High 42 dB(A)
Middle 38 dB(A)
Low 32 dB(A)
Quiet 28 dB(A)
Indoor (Heating) High 42 dB(A)
Middle 38 dB(A)
Low 32 dB(A)
Quiet 28 dB(A)
Sound Pressure Level Outdoor (Cooling) High 55 dB(A)
Outdoor (Heating) High 55 dB(A)
Sound Power Level Indoor (Cooling) High - dB(A)
Indoor (Heating) High - dB(A)
Outdoor (Cooling) High - dB(A)
Outdoor (Heating) High - dB(A)
Air Flow Rate Indoor High 2100 m3/h
Outdoor High 6750 m3/h
Static pressure range (Standard) 30 to 150 (60) Pa
Net Dimensions
Indoor
Height 270 mm
Width 1135 mm
Depth 700 mm
Net Dimensions
Outdoor
Height 1290 mm
Width 900 mm
Depth 330 mm
Net Weight Indoor 40 kg (88 lbs)
Outdoor 86 kg (190 lbs)
Connection Pipe Diameter Liquid 9.52 mm
Gas 15.88 mm
Drain Hose Diameter Indoor 35.7 mm
Outdoor 38.1 mm
Max Pipe Length (Pre Charge) 50 (20) m
Max Height Difference 30 m
Operation Range Cooling -15 to 46 °CDB
Heating -15 to 24 °CDB
Refrigerant Type R410A
Global Warming Potential 2,088
Charge 3,350 g
Scroll

Dimensions

Indoor Unit : ARYG45LMLA

Indoor unit

Optional Parts

Wired Remote Controller
UTY-RNNYM
Wired Remote Controller
UTY-RVNYM
Simple Remote Controller
UTY-RSNYM
Flange
UTD-RF204 (Round)
Flange
UTD-SF045T (Square)
Long-Life Filter
UTD-LF25NA
Remote Sensor Unit
UTY-XSZX
Drain Pump Unit
UTZ-PX1NBA
IR Receiver Kit
UTY-LRHYM